Jenn-Air 36 Downdraft Vent
Description
The Jenn-Air JXD7036YS is a professional-grade 36-inch telescoping downdraft ventilation system designed for larger cooktop installations and commercial-style ranges. This precision CNC template ensures accurate countertop cutouts for seamless integration in granite, quartz, marble, and solid surface materials. Featuring a powerful 600 CFM centrifugal blower and 14-inch telescoping rise, this downdraft system requires an exact 34.5" x 10.5" countertop opening with 0.25" corner radius for proper installation and operation. Our template is based on Jenn-Air's official dimension guide and provides all necessary measurements for professional-grade fabrication. The wider 36-inch format accommodates large cooking surfaces and provides enhanced ventilation coverage for multi-burner cooktop configurations.
Dimensions
- Overall Width
- 36"
- Overall Depth
- 12.125"
- Corner Radius
- 0.25"
Specifications
- Manufacturer
- Jenn-Air
- Model Number
- JXD7036YS
- Downloads
- 0
Related Templates
Jenn-Air 30 Downdraft Vent
Jenn-Air
Jenn-Air 30 Electric Cooktop
Jenn-Air
Jenn-Air 36 Electric Cooktop
Jenn-Air
Jenn-Air 30 Gas Cooktop
Jenn-Air
The Jenn-Air JXD7036YS is a professional-grade 36-inch telescoping downdraft ventilation system designed for larger cooktop installations and commercial-style ranges. This precision CNC template ensures accurate countertop cutouts for seamless integration in granite, quartz, marble, and solid surface materials. Featuring a powerful 600 CFM centrifugal blower and 14-inch telescoping rise, this downdraft system requires an exact 34.5" x 10.5" countertop opening with 0.25" corner radius for proper installation and operation. Our template is based on Jenn-Air's official dimension guide and provides all necessary measurements for professional-grade fabrication. The wider 36-inch format accommodates large cooking surfaces and provides enhanced ventilation coverage for multi-burner cooktop configurations.
Installation Overview
The Jenn-Air JXD7036YS installation requires careful coordination between countertop fabrication, cabinetry, and ventilation planning. The primary countertop cutout measures 34.5 inches wide by 10.5 inches deep with 0.25-inch corner radius. The unit's total footprint extends to 36 inches wide by 12.125 inches deep, demanding substantial cabinet space below for the motor assembly and ductwork connections. Like its 30-inch counterpart, the JXD7036YS features a reversible motor box that can be positioned on either side of the unit for installation flexibility around plumbing or electrical constraints. Countertop thickness should be at least 1.25 inches (3cm stone) to maintain structural integrity around the larger cutout opening. When fully extended, the downdraft rises 14 inches above the counter surface, requiring verification of clearance to overhead elements like pot racks or lighting fixtures. Electrical requirements include a dedicated 120V, 15-amp circuit routed through the cabinet base. The ventilation system accepts either 3.25" x 10" rectangular ductwork or 6" round ducting, with routing options through the floor or exterior wall. For island installations, floor ducting through the basement or crawlspace is typically most practical.
CNC Cutting Notes
Programming your CNC for the JXD7036YS requires attention to the larger cutout dimensions and maintaining tight tolerances across the extended width. Import the DXF template and verify the 34.5" x 10.5" opening dimensions before tool path generation. The 0.25-inch corner radius should be cut with a matching radius end mill or ball nose bit for exact conformance to manufacturer specifications. For granite and natural stone, maintain cutting speeds between 60-80 inches per minute with consistent water coolant flow to manage heat and prevent micro-fracturing along the cut edge. Quartz and engineered materials can typically accommodate faster speeds of 80-100 IPM, though harder quartz formulations may require speed reduction. The wider cutout span increases the risk of material movement or vibration during cutting, so ensure the slab is properly supported across its entire length with particular attention to the cutout area. Use an outside profile cutting strategy to maintain the cutout piece intact until final separation, preventing unexpected movement that could damage the edge quality. For brittle materials like marble or softer stones, reduce feed rates by 25-30% and employ multiple shallow passes rather than a single full-depth cut. Post-cutting, inspect all edges carefully for micro-chips or irregularities, paying special attention to the corner radii where stress concentrations are highest. Perform a dry-fit test of the actual downdraft unit before final installation to verify clearances and alignment with the cabinet structure.
Material Compatibility
The JXD7036YS template is engineered for compatibility with all professional-grade countertop materials commonly specified in residential and commercial kitchen projects. Granite and natural stone are ideal choices, providing excellent heat resistance and structural stability around the 34.5-inch wide cutout. The larger opening requires careful consideration of grain direction and natural fissures in the stone to avoid potential weak points. Quartz and engineered stone materials offer superior consistency and are highly recommended for downdraft installations due to their uniform strength properties and heat resistance up to 400°F. The non-porous surface also resists staining from cooking vapors and grease. Solid surface materials like Corian can be used but require verification that the specific product maintains structural integrity and heat resistance above 350°F under continuous cooking conditions. Laminate countertops are not recommended for downdraft installations due to heat sensitivity and insufficient structural strength around large cutouts. Concrete countertops are fully compatible when properly reinforced with steel mesh or fiber reinforcement, though they require professional-grade sealing to prevent moisture absorption from steam and cooking vapors. Stainless steel and other metal countertops are excellent choices for commercial applications, offering superior heat resistance and easy cleaning. Avoid wood and butcher block materials in the immediate downdraft area due to susceptibility to heat damage and moisture-related warping. When planning seam locations, maintain at least 8 inches of clear distance from the cutout perimeter to ensure adequate material strength and prevent stress-related failures.
Where to Buy
The Jenn-Air JXD7036YS 36-inch downdraft ventilation system is available through Jenn-Air's extensive network of authorized dealers and specialty appliance retailers. Purchase directly from the official Jenn-Air website at jennair.com, where you can access the complete product line and use their dealer locator tool to find certified installers near you. Leading online appliance retailers including Designer Appliances, US Appliance, AJ Madison, and Build.com maintain inventory of this model with competitive pricing and nationwide shipping options. For hands-on evaluation, visit authorized Jenn-Air showrooms where you can observe the telescoping mechanism in action and consult with trained specialists about installation requirements for your specific kitchen layout. Regional authorized dealers such as Metropolitan Appliance (Pacific Northwest), Wilson AC & Appliance (Texas), DeWhitt Appliance (Oregon), Mrs. G TV & Appliances (New Jersey), and Warner's Stellian (Midwest) offer local inventory, delivery, and professional installation services. These dealers often provide package pricing when purchasing the downdraft alongside compatible cooktops or ranges. Big-box retailers occasionally stock Jenn-Air ventilation products, though availability varies by location and season. For optimal pricing, request quotes from multiple dealers and inquire about seasonal promotions typically offered during spring remodeling season (March-May) and fall holiday sales (September-November). Professional kitchen designers and contractors can often access trade pricing through their dealer partnerships. When purchasing, confirm that the package includes all necessary mounting hardware, ductwork transition pieces, installation manual, and warranty documentation. Consider extended warranty options for long-term protection of the motor and electronic controls.