Description
6" x 84" backsplash template with Two Outlets Evenly Spaced for countertop fabrication.
Dimensions
- Overall Width
- 84"
Specifications
- Downloads
- 0
Related Templates
Extended seven-foot counter runs demand thoughtful electrical planning to ensure balanced power access across the entire workspace. This 6-inch by 84-inch backsplash template features two precision-cut outlet openings positioned at mathematically equal intervals, dividing the length into three equal sections of 28 inches each. The evenly-spaced configuration ensures users are never more than approximately 28 inches from power access regardless of where they work along the counter, meeting electrical code requirements while creating perfect visual symmetry. This balanced approach is ideal for prep counters, baking stations, island configurations, and commercial installations where appliances or equipment might be positioned at various locations along the extended run. The symmetrical outlet placement also enhances the aesthetic appeal of patterned or veined stone materials by maintaining visual balance. Professional fabricators serving upscale residential and commercial markets will appreciate how this template delivers both functional excellence and architectural sophistication.
Installation Overview
Successful installation of this evenly-spaced dual-outlet backsplash requires exceptional precision in electrical box placement given the extended length and symmetrical layout. Coordinate closely with the electrician to ensure both outlet boxes are positioned at exactly 28 inches and 56 inches from one end (or your specified spacing), measured to box centers, with both boxes at identical height above the countertop (typically 4 inches to box center). Even minor misalignment becomes magnified over the 84-inch span and symmetrical layout. Create a full-scale template or detailed dimensioned drawing for the electrician showing exact outlet positions referenced to a fixed point like a cabinet edge. During installation, use a three-person team minimum given the extended length and dual-cutout complexity. Dry-fit the backsplash first, threading both sets of wiring through their cutouts to verify perfect alignment. Any misalignment exceeding 1/4 inch should be corrected by repositioning electrical boxes before proceeding. Apply construction adhesive across the back surface, then carefully position the backsplash with all three installers working in coordination. Use multiple temporary supports every 18-24 inches to hold the extended backsplash firmly against the wall until adhesive cures for 24 hours.
CNC Cutting Notes
Programming this extended evenly-spaced dual-outlet template demands careful attention to material stability across the 84-inch length. Ensure your CNC table or waterjet bed provides adequate support and clamping along the entire span, with clamps positioned to avoid toolpath interference. Program both outlet cutouts first, before the perimeter cut, maintaining maximum material rigidity during machining. Use a 1/4-inch or 3/8-inch end mill for outlet cutouts, sizing to your specific outlet type (2.75" x 1.75" for duplex or 2.75" x 1.625" for Decora outlets). Feed rates of 80-100 IPM minimize corner chipping. The evenly-spaced positioning at approximately 28 and 56 inches from one end places both cutouts in the central two-thirds of the length with substantial material on all sides, reducing movement risk during cutting. After completing both outlets, add tabs between each cutout and the nearest edge plus additional tabs every 18-24 inches along the full length to prevent sagging during perimeter cutting. Execute the perimeter cut at 100-120 IPM using a 3/8" or 1/2" bit. For waterjet cutting, verify adequate travel distance and material support across the full 84-inch length. Post-cutting, use two-person handling with support from underneath to prevent stress at the dual cutout locations.
Material Compatibility
This 84-inch evenly-spaced dual-outlet template requires careful material selection and strict handling protocols. Granite in 3cm thickness is mandatory for this extended length with two centrally-positioned cutouts. The evenly-spaced outlets create three sections of approximately 28 inches each, with the material between cutouts being especially critical. Select granite slabs with favorable grain orientation and no natural fissures connecting cutouts to edges or between the two cutouts. Quartz engineered stone is ideal for this configuration, offering superior flexural strength and consistency across the extended length. The uniform composition ensures the material between cutouts maintains full strength without the natural weak planes that can occur in granite. Quartz's consistency also ensures both cutouts are identical in edge quality. Marble is technically possible at 84 inches with dual cutouts but only with 3cm thickness, exceptional material selection avoiding weak veining patterns, and extreme care during all handling. Most fabricators avoid marble for this demanding configuration. Quartzite provides outstanding strength for extended lengths and multiple cutouts, handling the mechanical demands excellently though requiring diamond tooling throughout. For all materials at this length and cutout configuration, 3cm thickness is non-negotiable - 2cm would be dangerously flexible and prone to breakage. Porcelain large-format slabs work well when cut via waterjet methods.
Where to Buy
Download this precision-engineered extended template from the Slabwise professional library for immediate integration with CNC and waterjet fabrication systems. Compatible with all major control software including Alphacam, Mastercam, RhinoCAM, VCarve Pro, and waterjet platforms from Flow, OMAX, and Jet Edge manufacturers. For electrical outlets in evenly-spaced configurations, specify matching devices from Leviton, Lutron, Legrand, or Cooper Wiring Devices to maintain visual consistency. Common specifications include both outlets as 20-amp rated (recommended for modern kitchen counter circuits), both tamper-resistant (required by code in many jurisdictions), or one standard and one GFCI if positioning places one outlet within 6 feet of a sink. Source stone from suppliers with large-format inventory including MSI, Daltile, Arizona Tile, or Bedrosians, verifying slab dimensions accommodate 84 inches plus edge finishing allowance. This template serves fabricators specializing in high-end residential installations, luxury condominiums, commercial kitchens, and architectural projects where extended seamless runs with balanced electrical access represent design excellence.